Let us know what you're looking for by filling out the form below. Contact Us; Contact Us; Custom Financing Solutions; Same Day Shipping Program; Olympus Scientific Cloud; Olympus. Formatting the device this way may corrupt the device's firmware, rednering it non-functional. Note: Virtually all commercial operating systems now have native support for the USB Mass Storage Device Class protocol, and older operating systems such as Windows 98 SE and Mac OS 8.5.1 can support it through third-party drivers. However, if the.
Older drivers may or may not work with Win 10 - it depends. 16 bit drivers- software- are incompatible with a 64 bit O/S. Software Downloads Olympus IMS It seems there is 32 bit and 64 bit software- I can't see which is a critical driver there. Otherwise you can try installing the driver in compatibility mode. (Rt click, troubleshoot. MIC-D is comprized of inverted zoom optical system, with a built in digital image pickup device for CMOS. The image is displayed from the monitor of a personal computer(PC). (2) Service life 5 years 2. Features (1) MIC-D is powered by the PC via the USB port cable.
- 2Installation
Olympus IX81/IX71/BX61/BX51 adapter
Summary: | Controls Olympus IX81, IX71, BX61, BX51 microscopes | ||||||||||||
Author: | Jeff Kuhn and Arthur Edelstein, BX61 support added by Shalin Mehta | ||||||||||||
License: | not Open Source | ||||||||||||
Platforms: | Windows, Mac OS X (through serial port) | ||||||||||||
Available since version: | 1.3.22 | ||||||||||||
Default serial port settings: |
|
Installation
Cabling and DIP switches
Olympus microscopes generally require straight-through (not null-modem) RS-232 cables (confirmed with an IX2-UCB).
These serial port settings require all DIP switches on the front of the 'Frame Control Unit' (the box connected to the serial cable) to be in their default position: off (zero). Switching of these DIP switches must be done while the unit is turned off.
BSW Software
The IX-81 seems to require the Olympus BSW software to be installed and configured otherwise Micro-Manager complains about 'Error in device OlympusHub: Error code 17 (11 Hex)'. Make sure you can connect successfully in BSW, i.e. 'Log in'.
Download Olympus Port Devices Driver
Hardware Configuration Wizard
Add an Olympus Hub device to your hardware configuration and choose its serial port. Other devices (stage, filter wheel, etc) then communicate to the hardware through the (software) Hub.
Device Configuration
There are two modes of Control: Computer and 'Manual + Computer'. The former is faster, but disables the manual controls. The latter is slower, but allows you to manually control the turret positions, focus drive, etc.
If you are using the Olympus ZDC unit (Z-drift correction), you will need to set two properties: the ObjectiveTypeSetting and the SearchRange (a size in microns). Choose MeasureOffset->Now to fix your current z offset, and then running autofocus will return the focus drive to that offset.